8:Fiber Optic Emitter Characteristics

Written by Bruce Robertson, 97. Reviewed Dec 2005. © Kingfisher International

prev add to favourites print next Introduction

Measurement sources used for measuring fiber optic attenuation vary enormously in cost and performance. This application note explains what it is all about.

The Range

Inexpensive Surface emitting LED sources are used for testing multimode fiber. They emit a low power level with good power stability, however their spectral characteristics are very poor. LED sources used for certification may require special spectral and beam geometry characteristics to ensure consistent measurement results.
Moderate Fabry-Perot laser sources are used for general single mode attenuation measuring. Lasers provide much better spectral accuracy than LEDs, and much higher power output. However they tend to have problems with power stability.
If a broader spectral output is required for single mode measuring, edge emitting LEDs are available, however their power output tends to be excessively temperature sensitive.
Expensive Laser sources can be enhanced in various ways. The most common enhancements are:

  • Fabry-Perot of DFB laser with tighter initial wavelength accuracy.
  • Better wavelength stability using a Bragg grating and / or temperature control via a Peltier device.
  • Wavelength tuning capability. A wide range of cost and performance is available for various specialist applications.
  • Extra power stabilising techniques.
  • Multiple lasers connected to a single connector port, which results in faster operation.

Center wavelength accuracy

The peak emitted wavelength of any source is usually called the center wavelength. In Fabry-Perot laser sources used for attenuation testing, the initial tolerance is typically ± 30 nm, which affects both attenuation effects, and measurement accuracy. In addition to this tolerance, temperature sensitivity of around 0.4 nm / °C creates further variation. The temperature effect can be virtually eliminated by use of temperature controlled emitters.

To put all this in perspective: The effect of 0 – 40 °C temperature induced wavelength change will alter the attenuation dB measurement of a 50 Km single mode link by typically ± 0.25 dB. However the link attenuation uncertainty caused by an initial tolerance of ± 30 nm would be about ± 0.95 dB. Note that the wavelength uncertainty of operational systems may be of a similar amount, in which case there may be some mis-match between the measured attenuation, and the attenuation seem by the operational system.

It is possible to select devices with better initial tolerances (eg for measurement purposes), however this has little practical benefit if the wavelength of installed systems also has a large uncertainty. As a practical compromise, a laser center wavelength tolerance of ± 20 nm is often specified for sources.

Course WDM lasers usually have a wavelength tolerance of about 3 nm, and DWDM lasers have a much tighter tolerance still. However these DFB type lasers are not so ideal for measurement purposes, since coherent interference noise in cables tends to produce more measurement uncertainty. When DFB lasers are used, it is preferable to ensure a low reflection environment.

Spectral width

LED laser spectral width and beam geometry comparison

Fig 8.1: A comparison of the spectral and spatial distribution of Lasers and LEDs.

Sources emit light over a range of wavelengths. The spectral width may be specified in terms of FWHM, or Full Width Half Maximum. This is OK for transmission systems, but in measurement situations, there may be enough power outside this specification to affect attenuation measurements.

For example, an LED emits over a broad spectrum of 30 – 200 nm, depending on the type. This broad spectral width tends to overwhelm the issue of initial center wavelength tolerance. If spectral width, initial tolerance and temperature effects are included, a 1300 nm LED could be emitting some light anywhere over 1150 – 1450 nm. The 850 nm LED spectral width is generally around 50 nm FWHM.

Lasers have a much narrower spectrum of up to 5 nm FWHM, depending on the type. Therefore for loss testing purposes, the laser center wavelength tolerance is more important, and the spectral width can generally be ignored.

Temperature changes do not significantly affect spectral width, however temperature changes can cause sudden changes to laser operating modes. These sudden changes can cause fluctuations in output power, attenuation and meter performance.

Power stability

The output power stability of sources is a significant issue:

Source power level

Source nominal power levels vary quite widely. The actual power level is not often very important, since a reference is taken before starting work. It is the stability that is critical. When determining approximately how much power is required, the following factors should be taken into account:

Multimode Attenuation Standards Compliance

In order to achieve repeatable and worst-case attenuation results across the industry, multimode sources should now comply with USA and European standards which define the source center wavelength tolerance, spectral width and Coupled Power Ratio. The standards require loss measurements to be performed using the bi-directional method at two wavelengths, using a standards compliant LED source.

Other issues

Battery systems: Battery life is obviously a major convenience issue. Some Kingfisher sources have a battery life of up to 190 hours. Also important will be an auto-turn off feature, and low battery indicator. Where possible, alkaline batteries are now preferable to re-chargeable types, due to greater convenience, higher capacity, and longer charged shelf life. Should re-chargeable batteries be required, NiMH cells are preferable to NiCd cells, since they give longer run times and avoid the problem of disposing of toxic cadmium waste.

Connector: An interchangeable connector is obviously highly desirable, allowing the user to change connector styles. An interchangeable connector also allows better end face cleaning during use.

Ease of use: how long will it take to train operators? Kingfisher sources with similar general features and controls are available over the full spectrum of price and performance. One method of operating all sources, could save a large organization plenty on training costs.

Sources with multiple wavelengths from one connector provide greater productivity when performing multi wavelength attenuation measurements. The following alternative ideas may also improve productivity:

Safety

The two main regulations governing the safety of sources are the international standard IEC 60825 2011, and the USA regulation 21CFR1040.10. As applied to fibre optics, both standards generally draw a distinction between safety levels above or below 1 mW or 0 dBm. Power levels above this may attract onerous complications in relation to work practices, interlocks and safety issues, and are therefore to be avoided where possible.