10C: Measuring Attenuation
Using A Single Source and Meter

Written by Bruce Roberson 97-03. © Kingfisher International

prev add to favourites print next Introduction

This is the simplest form of attenuation measurement. Patch leads should be of similar type to the DUT. F or multimode measurements, a mandrel wrap forms part of the source reference condition. Communication is required between the two operators.

Method

1. Clean the connectors. Connect the source and meter using two patch leads and a through connector (or one patch lead and no through connector for the building cabling method), set the source and meter wavelengths. Allow the source to warm up and stabilise. Measure and record the reference power P1 dBm [For meters which have a relative dB measurement facility, put the meter in relative mode and set the reference]. For dual wavelength work, also reference the other wavelength at this point, after a further warm up period.

Note: it is good practice to occasionally check your patch leads by reversing them (eg the other ends go into the through connector), and re-measuring the reference value, which should only deviate within the expected tolerance of your connectors.

Diagram

2. Leave the patch leads connected to the instruments (or the one patch lead on the source for the building cabling method), since removing them adds to measurement uncertainty.

3. Insert the DUT into the measurement set up, using an using extra through connector if needed, and record measurement P2 in dBm [if the same reference value was used, the attenuation is displayed directly in dB. Step 5 is not required]

Diagram

4. Remeasure the source power as in set-up 1, to verify the source drift remain within acceptable limits.

5. Calculate the attenuation (dB) of the link as: Link attenuation in dB = P1 – P2

6. Repeat at the same wavelength for the other fibers (the order of 5 & 6 may depend on source warm up characteristics)

7. For dual wavelength measuring, change the source wavelength, wait for the source to warm up, then go back to step 3.

Disadvantages

In this situation ‘Autotest’ type features can result in better measurement confidence, lower skill requirements and twice the productivity for dual wavelength measurements, since both wavelengths are measured in one operation, and the attenuation is displayed directly.

Key

Connectorised link
Patch Cord
Through adaptor
Source, incl. mandrel wrap if multimode
Meter
DUT Device Under Test (system being tested)

[instructions on use of the relative mode are in italics]